Configure the Data Access Layer (DAL) file on the source system

Configure the Data Access Layer (DAL) file on the source system

  • Last UpdatedApr 24, 2025
  • 1 minute read

In the example below, configurations on the Development (DEV) system (pdcdev) are transferred to the Test (TST) system (pdctst).

The configuration steps are as follows:

  1. On the source computer where you plan to perform Pivot and Transfer, create a folder called pdctst under %DNADataRoot%\ADE\config\DAL\.

  2. Under the %DNADataRoot%\ADE\config\DAL\pdctst directory, create a folder called control_room.

  3. In the %DNADataRoot%\ADE\config\DAL\pdctst\control_room directory, create a Data Access Layer (DAL) file for the Pivot and Transfer configuration. For example:

    DALConfig_DBEDIT.xml

  4. Add the target system driver alias with the DBEdit driver-type configuration.

  5. Configure the DriverAlias accordingly.