Virtualflowcomputer table details

  • Last UpdatedApr 24, 2025
  • 3 minute read

The virtualflowcomputer table is used by the Virtual Flow Computer (VFC) application. The virtualflowcomputer table is used to contain configuration data and totalized runtime data for a set of meters operating in parallel. The virtualflowcomputer table contains the following internal fields:

Internal Field Name

Data Type

Description

accessFlag

displayname

Display that accesses this record.

autoInh

oas_boolean_t

Is the VFC inhibited due to an auto-inhibit operation?

autoInhPath

path

The path to the status or multistate point to auto-inhibit.

batchGuid

GUIDstring

When the Batch ID is changed for a given Virtual Flow Computer in ADE, a GUID is automatically generated. This field is not visible in ADE.

batchId

batchname

Optional value to use for Batch ID in batch tracking.

csw

double

Correction for sediment or water (0-100%).

DailyIntegrated

PeriodicIntegration

Daily integrated data.

dataset

doas_dset_slot

This field indicates the dataset to which the record is assigned. Datasets are used to associate the record with the privileges assigned for each system mode. Once a record is assigned to a dataset value, the dataset can only be changed to a value for which the system has a privilege record.

description

description

A description of this VFC point, up to 47 characters in length.

dsysControl

oas_boolean_t

Indicate whether the point is controllable from the local system.

enastates

string80

States that enable a meter device.

flag

flags

For information on the flag structure, see Flag structure details.

flowrate

double

Gross Standard Volume (GSV) flow rate.

flowrateUnitShort

string16

Short form units for flow rate for the record.

gsv

double

GSV.

gv

double

Gross Volume.

hourlygsv

double

Hourly GSV.

hourlygv

double

Hourly GV.

HourlyIntegrated

PeriodicIntegration

Hourly integrated data.

hourlyiv

double

Hourly indicated volume.

hourlynsv

double

Hourly Net Standard Volume (NSV).

inhibit

oas_boolean_t

Manual inhibit flag.

inhstates

string80

States that inhibit a meter device.

input

AssignmentInputStruct

The VFC point assignment configuration details.

iv

double

IV.

LastIntegrationRollup

internaltime

Datetime of last integrated data rollup.

lasttime

internaltime

Last processing time.

lasttopofhour

internaltime

The last top of hour processed time.

Mass

double

Mass in pounds.

meterFactorAlarm.alminh

oas_boolean_t

Inhibit alarms associated with a Meter Factor (mtrfact) record?

meterFactorAlarm.evtinh

oas_boolean_t

Inhibit events associated with a mtrfact record?

meterFactorAlarm.sev

sev_enum

Alarm severity.

MonthlyIntegrated

PeriodicIntegration

Monthly integrated data.

name

pntname

The unique name of this virtualflowcomputer record. The name can be up to 32 characters in length.

nsv

double

NSV.

PeriodicIntegrationEnabled

oas_boolean_t

Indicates periodic integration is enabled.

pipelineslt

pipelineslot

The batch track region associated with this virtualflowcomputer record.

pointClass

configenumslot

The point class category contains multiple configuration enumerations used for categorical configuration of points.

pointSubClass

configenumslot

The point subclass category is a configurable enumeration category used for categorical configurations. It cannot be used for configurable alarms and events.

ppltask

enum_ppltask

The type of association for the virtualflowcomputer record to the Batch Tracking pipeline.

presimiv

double

Pre-simulation Indicated Volume (IV).

presimgsv

double

Pre-simulation gross standard volume.

presimgv

double

Pre-simulation gross volume.

prodtype

prodtypeslot

The prodtype record that represents the product that flows through the meter.

ptnum

slot

Slot number in the RealTime database.

rtu

remoteslot

The name of the remote record corresponding to the Remote Terminal Unit (RTU) associated with this virtualflowcomputer record.

simulation

vfcsimfield

Simulation fields.

smoothedflowrate

double

Smoothed GSV flow rate.

TopOfDay

internaltime

Time of day (HH) for the Top of Day (TOD) to occur.

topOfDayAlarmActive

oas_boolean_t

Indicates that there is an active Top of Day configuration error alarm on the Virtual Flow Computer record.

TotalIntegrated

PeriodicIntegration

Total integrated data.

unitprofile

unitprofileslot

The name of the unitprofile record used to assign the units of measurement.

useAutoInh

oas_boolean_t

Use a state point to determine inhibit.

UsesGroupTopOfDay

oas_boolean_t

Indicates that TopOfDay is overidden by groupTOD.TopOfDay.

vfcassigntype

enum_pipelineassigntype

Pipeline task assignment type configuration details.

vfcTime

internaltime

Time from rate. Use for PLM stale time check.

wa_press

double

Weighted Average Pressure (WAP).

wa_temp

double

Weighted Average Temperature (WAT).

wa_dens

double

Weighted Average Density (WAD).

wa_obs_dens

double

Weighted Average Observed Density (WAOD).

wa_cws

double

Weighted average Correction for Sediment and Water (CSW) (0-100%).

wa_flowrate

double

Weighted average GSV flow rate.

wa_ctl

double

Weighted Average Temperature Correction Factor (WACTL).

wa_cpl

double

Weighted Average Pressure Correction Factor (WACPL).

YearlyIntegrated

PeriodicIntegration

Yearly integrated data.

Related Links