Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA Enterprise SCADA

Modify the standalone changeset configuration setting

Modify the standalone changeset configuration setting

  • Last UpdatedApr 24, 2025
  • 1 minute read

Note: For information on overriding default configuration settings, refer to Modify configuration settings.

To modify the standalone changeset configuration, the AVEVA Enterprise SCADA configuration settings JSON file on every application with the Management of Change (MoC) tools product installed must be modified. The JSON file is installed to the following location, but must be copied and configured in the %DNADataRoot%, as described above:

  • %DNAInstallRoot%\RealTime\config\settings\ManagementOfChange_Tools.json

To modify the standalone changeset configuration

  1. Create or open the ManagementOfChange_Tools.json file in the %DNADataRoot%\RealTime\config\Settings directory.

  2. Add or edit the ManagementOfChangeStandaloneChangesetFlagMetadataName configuration setting override, and set it to the desired flag (default value is QC_Only).

    The following example shows the default content of the configuration settings JSON file:

    {

    "ManagementOfChange": {

    "ManagementOfChangeStandaloneChangesetFlagMetadataName": "QC_Only"

    }

    }