The size of Data Array is different from the size of Quote Array

The size of Data Array is different from the size of Quote Array

  • Last UpdatedApr 24, 2025
  • 1 minute read

When the size of Data Array is different from the size of Quote Array, you will see an error message similar to the following:

07/07/97 23:45:13 - Failed to update EFM..dailyChart Failed to load: Data file Line 0: Size of data array different from size of quote array. (27,852559861,1,852642000,300,NULL,82140.000000,NULL,125.000000,NULL,60.000000,NULL,0.000000,2.200000,22000.000596,212.325543,NULL,NULL)

This issue typically occurs when a column is added to the table on the source system but not added to the destination system.

To solve this problem

  1. Use the -p option of DPutil to compare the table definitions.

  2. Ensure the number of columns in the data file correspond to the number of columns in the table.