The dataexchange table is used by the Generic Import and Export application. The records in the dataexchange table are used to reference AVEVA Enterprise SCADA tag names with external system tag names. The dataexchange table contains the following internal fields:

Internal Field Name

Data Type

Description

customer

pntname

The name of the interface customer.

customerTag

string128

The customer tag name.

dataset

doas_dset_slot

This field indicates the dataset to which the record is assigned. Datasets are used to associate the record with the privileges assigned for each system mode. Once a record is assigned to a dataset value, the dataset can only be changed to a value for which the system has a privilege record.

format

string128

The format string to use when exporting this tag if the format field in the ImportExportConfig table is set to DATABASE.

pointPath

string128

The name of the fully qualified AVEVA Enterprise SCADA point name.