Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA Enterprise SCADA

Pivot and Transfer from a Row Edit dialog box

  • Last UpdatedApr 24, 2025
  • 2 minute read

You can perform a Pivot and Transfer from a Row Edit dialog box to transfer a single RealTime database (RTDB) table record.

  1. Open the Row Edit dialog box (source) for the record you want to transfer.

    Note: Pivot and Transfer will only transfer one record to the target system at a time.

  2. Select Tools > Pivot and Transfer.

    The System Selector dialog box appears.

  3. In the Select Target System field, select a valid target system from the list.

  4. Select Transfer.

    Note: If the Select Target System field is empty (or has an invalid target system), an error message will appear reminding you to select a target system. Select OK on the error message, and select a valid target system from the list.

    Either an Advanced Database Editor (ADE) login dialog box or the target Row Edit dialog box appears.

  5. If required, enter your User name and Password, and Select OK in the ADE login dialog box.

    The target Row Edit dialog box appears.

  6. Select Record > Save Changes.