Check the status of Datapump
- Last UpdatedApr 24, 2025
- 2 minute read
Use the DPutil command to check the status of Datapump.
Syntax
DPutil -S <source> -D <destination> -d <database> -t <table> [-r] [-R] [-i] [-I] [-K] [-e]
|
Parameter |
Description |
|---|---|
|
-R |
Returns all datapump column values that are important to the configuration of the data transfer including the status columns returned using the -r option. |
|
-i |
Returns the Datapump entries that failed or are in transit. |
|
-I |
Prints the failed Datapump entries. |
|
-K |
Returns the number of rows queued in each configured KeyTable. This information can indicate whether the transfer is backing up or working. |
|
-e |
Returns the Datapump events that occurred in the past 24 hours. |
|
-S <source> |
Identifies the source connection. The default is MS:(local). The source is specified as: [system:[RDBMS:]][userid/passwd@]service For example, -S MS:localhost\OASYSHDB. The system must be specified when you only want to see information for a particular destination system. RDBMS can be SYB, FILE, BINFILE, ORA, ODBC, or MS. Use DPutil -h to obtain the list of RDBMS types available on your system. |
|
-D <destination> |
Identifies the destination connection. The destination is specified in the same format as the source where the destination database is located in the same domain; for example, <system>\oasyshdb. If the destination is located in a different domain, the Data Access Layer (DAL) driver, alias, and Remote Client Service (RCS) must be specified. For example: main:MSDAL:Dir=sub\\remote_RCS_XFER;Alias=Historical_XFER Where main is the DPSystem and sub is the destination system in the untrusted domain. |
|
-d <database> |
Identifies the database that contains the table to be compared between systems. |
|
-t <table> |
Identifies the table to be compared between systems. |