Understanding the attribute table
- Last UpdatedApr 24, 2025
- 7 minute read
The attribute table is accessed by opening the View menu in the Advanced Database Editor (ADE) and selecting System. The attribute table records are used to define the different images that will be shown in the data attribute icons depending on the status of the different flags of the point.
Notes: The image below shows the default values for the attribute table.

|
Field |
Description |
|---|---|
|
Name |
Enter a name for the attribute. |
|
Description |
Enter a description for the attribute. |
|
Field Name |
To select one of the fields available in your system:
The value for the flag determines whether the attribute is active or not. The Field Name must be the name of a field included in the flags or the replicatedFlags structure with type oas_boolean_t. If you provide a name that is not part of the flags or the replicatedFlags structure, the record will not save and an error will appear. Note: There are some special fields in flags structure (sevint, tag, and flexTag) that are not oas_boolean_t type, but can be used to describe attributes. A special logic is defined for them to process the image to be used. Refer to the Image Field description for more information. Alarm icons in the attribute table may flash. If you configure an attribute that has the sevint or alarm field assigned to an icon, the Control Room Management (CRM) object can be configured so that the icon will flash for an unacknowledged alarm. Note: You should only assign either an alarm severity or alarm state to a single icon. API-1165 and Abnormal Situation Management (ASM) both call for alarm severity only being displayed in the icon. Assigning an alarm state goes against the recommended practice. Alarm state is depicted through colors only for API-1165 and not through an icon. There is no mention of alarm state in ASM. |
|
Is Inverted |
When this checkbox is selected, and the value of the configured field name is no, the attribute will be considered active. |
|
Precedence within Icon |
This precedence defines the stack options for the attributes. The image used for each icon will be the one that is configured in the attribute assigned to the icon that is active and has the highest precedence. For the precedence, the values are 1 to 50. Lower numbers correspond to a higher precedence. Note: The value for this property must be different for all records assigned to the same icon. If there are two rows with the same precedence, the same icon position, and both attributes are active, the behavior is unpredictable. |
|
Image File |
The content of this field is determined by the type of attribute that you want to define. There are two types of attributes: regular attributes and special logic attributes. Note: A question mark (?) will be drawn in the element in the easy eXtended Operator Station (ezXOS) if the image file specified does not exist. |
|
Regular Attributes A single defined image will be shown when the attribute is active. For regular attributes, the Image File field contains the image that will be shown when the attribute is active. The image file must have the .gif extension and must not contain:
|
|
|
Special Logic Attributes Attributes configured with certain database field names can show different images when the attribute is active (depending on certain conditions). It is the responsibility of the customer to create as many images as possible to match the possible values of the images. The possible values depend on the field names and are described below:
|
|
|
|
|
|
|
flexTag: This attribute shows a different image based on the flexible tagging configuration. For the flexTag field name, the content of the Image File field is ignored. The images that will be used will be the ones configured in the flexible tagging configuration. |
|
|
|
|
Icon Position |
Select the icon that the attribute is mapped to. If you select Unassigned, the attribute will not be used in any icon. The possible values are Icon1, Icon2, Icon3, and Unassigned. Note: You may assign only one of the alarm severity or alarm state configurations to an icon. The other must remain Unassigned. |
and select the desired field name in the Field Name Selector dialog box.

)