AVEVA Enterprise SCADA

InterpTrend

  • Last UpdatedJul 05, 2024
  • 2 minute read

The function of this Business Logic Tier (BLT) is to retrieve collection / summary data from the RealTime database (RTDB) collect table and the Historical database TimeSeries or timeline table. It interpolates the starttime and endtime values from previously collected values for all collect value points.

The data returned includes the following information:

  • collection time

  • summarized or collected value

  • data quality

  • index of the active data quality attribute with the highest precedence

Syntax

InterpTrend <tablename> <tagname> <columnname> <starttime> <endtime> [showFieldTime]

 

Parameters 

Name

Description

tablename

The name of the RTDB / Historical database table that contains the data to be accessed. This can be any of the following: collect, hour, day, month, or year.

tagname

The name of the point to be viewed.

columnname

The column of the RTDB / Historical database tables to view. This can be any of the following: value, minimum, maximum, and average. If the table name is collect, the only column allowed is the value column. If the table name is not collect, then the value column is the instantaneous value of the point.

starttime

The time from which to begin the trend data. This is entered as an integer representing Greenwich Mean Time (GMT) time, which is localized to your time zone.

endtime

The time at which the trend data stops. This is entered as an integer representing GMT time, which is localized to your time zone.

showFieldTime

If the table name is collect, enter 1 to display the field timestamp of the collection. Enter 0 or NULL to not display the field timestamp of the collection.

 

Example

InterpTrend 'collect', 'analog.0analog.curval', 'value', 1401375720, 1401376860, 1

 

Time

Milliseconds

Value

Status

fieldTime

field Milliseconds

dqFlag

1401375720

0

2

O

1401375720

0

3

1401375780

0

2

O

1401375780

0

3

1401375840

0

2

O

1401375840

0

3

1401375900

0

2

O

1401375900

0

3

1401375960

0

2

O

1401375960

0

3

1401376020

0

2

O

1401376020

0

3

1401376080

0

2

O

1401376080

0

3

1401376140

0

2

O

1401376140

0

3

1401376200

0

2

O

1401376200

0

3

1401376260

0

2

O

1401376260

0

3

1401376320

0

2

O

1401376320

0

3

1401376380

0

2

O

1401376380

0

3

1401376440

0

2

O

1401376440

0

3

1401376500

0

2

O

1401376500

0

3

1401376560

0

2

O

1401376560

0

3

1401376620

0

2

O

1401376620

0

3

1401376680

0

2

O

1401376680

0

3

1401376740

0

2

O

1401376740

0

3

1401376800

0

2

O

1401376800

0

3

1401376860

0

2

O

1401376860

0

3

(20 rows affected.) 

Comments

This procedure is primarily used by easy eXtended Operator Station (ezXOS).