Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA Enterprise SCADA

Specify a connection string

  • Last UpdatedApr 24, 2025
  • 1 minute read

Note: For information on overriding default configuration settings, refer to Modifying Configuration Settings.

The RTU Composer application configuration allows you to specify the RealTime database (RTDB) Microsoft SQL access connection string, which disables the System Selector prompt in the RTU Composer and loads the connection string directly from the RTU Composer configuration file (RTUComposer.json). For more information on working with System Selector, refer to Create a simulation configuration file.

To specify a connection string

  1. In the %DNADataRoot%\Tools\config\Settings directory, either create or open the RTUComposer.json file.

  2. In the rtdbConfiguration object, modify the value of the connectionString key as per the example below:

    "rtdbConfiguration": {

    "connectionString": "FIL=MS Access;DSN=localrtdb"

    }