AVEVA Enterprise SCADA

Tables

  • Last UpdatedNov 02, 2023
  • 1 minute read

Required Properties

  • Table Properties

    • name

    • description

    • At least one key

      Note: If the table will contain configuration fields for the Management of Change (MoC) classification, it must contain a unique key.

    • At least one field

  • Key Properties

    • name

    • type

      Note: type must not be a table, null, empty, or whitespace.

    • description

  • Field Properties

    • name

    • type

      Note: type must not be a table, null, empty, or whitespace.

    • description

Example

{

"name": "Table1",

"description": "Table1 description",

"keys": [

{

"name": "name",

"type": "pntname",

"description": "name description",

"unique": true

}

],

"fields": [

{

"name": "field1",

"type": "double",

"description": "offset"

}

],

"dimension": 80000,

"slotName": "table1slot",

"pubSubTopicKey": "name"

}

In This Topic