Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA Enterprise SCADA

Station table details

  • Last UpdatedApr 24, 2025
  • 3 minute read

The Station Monitoring application uses station records to store station configuration. From a telemetry standpoint, a station is a collection of remotes (RTUs, PLCs, flow computers, etc.) at a single location such as a measurement station, or a pump or compressor station. The station table contains the following internal fields:

Internal Field Name

Data Type

Description

accessFlag

displayname

This flag is used by the easy eXtended Operator Station (ezXOS) to determine whether a table is being modified through the Advanced Database Editor (ADE). If the flag is set, access to the table is denied.

Address1

stn_str32

Physical address of the station.

Address2

stn_str32

Mailing address of the station.

alarm_counts

stnalarmcount

This field provides an array of alarm counts for each severity. The counts represent alarms from the station and any records that reference the station (for example, telemetered records).

ambTemp

float

Ambient temperature.

annunReset

isolateArray

Annunciator reset.

antiSurgeCmds

isolateArray

The Anti-Surge Command (ASC) command points.

atmPress

float

Atmospheric pressure.

assetId.assetIdComment

stn_str32

These fields allow the AVEVA Enterprise SCADA system to be a launching point for interacting with third-party asset-management systems.

assetId.assetIdDesc

stn_str32

assetId.assetIdLoc

stn_str32

calcnames

stnnamearray

Calculation names selected.

calcs

stncalcarray

Calculations selected.

City

stn_str32

The name of the city in which the station is located.

contact

stnContactArr

Contact data from WMS.

contractPres

float

Contract pressure.

County

stn_str32

County of station.

customer

stn_str32

Customer name.

dataset

doas_dset_slot

This field indicates the dataset to which the record is assigned. Datasets are used to associate the record with the privileges assigned for each system mode. Once a record is assigned to a dataset value, the dataset can only be changed to a value for which the system has a privilege record.

dataSrc

dataSource

Data source for the station.

description

description

A description of this station point, up to 47 characters in length.

desspt

stndoubleArray

Array for the desired setpoint value.

displayName

pntname

The name of the display associated with the station.

dsysControl

oas_boolean_t

Does the local system control this station?

downStream

pntname

The name of the station immediately downstream from the current station.

esd

isolateArray

ESDs and command points.

expFlow

float

Expected flow path.

expFlowTime

internaltime

Time expected flow changed.

extractionStn

extraction

Extraction station type.

fax

stn_str16

The fax number associated with the station.

flag

flags

For information on the flag structure, see Flag structure details.

flowTol

float

Flow tolerance.

group

groupslot

This field shows the group that this point is associated with for alarming.

landlegal

pntdescription

Legal land description.

lateral

pntname

Lateral drawing number.

latMP

float

Lateral mile post.

leftStream

pntname

Left stream station.

lnk_1

pntname

Navigation link 1.

lnk_2

pntname

Navigation link 2.

locationID

unsigned long

Station ID.

localmode

oas_boolean_t

Local mode lock.

isolate

isolateArray

Isolate and command points.

mapCoords

pntdescription

Station map coordinates.

mcppc

float

Current percentage of contract pressure.

microwave

stn_str16

Microwave number of the station.

mlMP

float

Mainline mile post.

mop

float

Maximum Operating Pressure.

mopPath

path

MOP pressure path.

moppc

float

Current percentage of the MOP.

mostSevAlm

char

Highest severity alarm.

mostSevAlmCol

char

Color of the highest severity alarm.

ms_name

pntname

The name of the meter associated with the station.

ms_num

pntname

The number of the meter associated with the station.

mtrNumber

stn_str16

The string version meter number.

name

pntname

The unique name of this station record.

note

longstring

Note.

number

unsigned long

Meter station number.

numCalcs

int

Number of calculations selected.

numInstances

int

The number of instances in the station.

OWriter

short

Other writer.

phoneNo

stn_str16

The primary phone number associated with the station.

phoneNo1

stn_str16

A secondary phone number associated with the station.

pipeline

pipelineslot

Pipeline number.

ptnum

unsigned char

This field represents the record’s slot number in the database.

PWriter

short

Prod writer.

QWriter

short

Qual writer.

realtime_gq

pntname

Zone Gas Quality (GQ).

rightStream

pntname

Right stream station.

runData

mtrStnData

Run data for displays.

schCoord

schCoords

Coordinates for calling schematics.

snchtime

internaltime

Time of the last expected flow path change.

spHeatCap

float

Specific heat capacity.

start_check

check_array

Product types checked on unit start.

State

stn_str32

The name of the state in which the station is located.

StationID

stn_str32

Station ID.

stationStatus

stn_str16

Station status.

stationType

configenumslot

The type of station.

stnAnalysisKey

stn_str32

Station analysis key.

stnData

mtrRunData

Station data for displays.

stnStatus

stationstatus

Station status.

stnSymbol

symbolstring

Station symbol.

stnTemplate

pntname

The station display template.

stop_check

check_array

Product types checked on unit stop.

stream_gq

stream_gqs

Stream GQ.

string_data

stn_str_arr

For string data.

unack_alarms

long

This field provides the number of unacknowledged alarms for the station, and all records that reference this station (for example, telemetered points).

upStream

pntname

The name of the next station upstream from the current station.

Zip

stn_str16

The zip code associated with the station.

zone_gq

pntname

Zone GQ.

Related Links