Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA Enterprise SCADA

Set up permissions for users

  • Last UpdatedApr 24, 2025
  • 3 minute read

Set up permissions for users so they can access messages.

To set up permissions for users

  1. Open the Network Management Console (NMC).

  2. Right-click on Permission and select New Permission.

  3. Add the following four permissions:

    • DNA Permission - OpLog Admin

    • DNA Permission - OpLog Operator

    • DNA Permission - OpLog Supervisor

    • DNA Permission - OpLog Viewer

  4. For each of the permissions added in the step above, add the groups and/or users that should be granted the permission.

    The example below illustrates the process for granting OpLog permission to Private OASyS DNA Groups for Authorities.

    1. In the right frame of the NMC, right-click on the new permission and select Properties.

      The DNA Permission Properties dialog box appears.

    2. Select the Members tab.

    3. Select Add Private OASyS DNA Account.

      The Select Private OASyS DNA Groups, Private OASyS DNA Users, Authorities dialog box appears.

    4. Select the DNA authority with the same name as the permission.

    5. Select Ok.

    6. Assign users to the DNA Authorities containing the newly created OpLog permissions.

  5. Open Microsoft SQL Server Management Studio.

  6. Under Logins, add the new or existing users you set up with the authority to access the Controller Messaging application.

  7. For each user you add in the step above, right-click on the name and select Properties.

    The Login Properties dialog box appears.

  8. In the Explicit tab on the Securables page, select Connect SQL to grant the user Microsoft SQL access.

  9. Select the User Mapping page.

  10. Under Users mapped to this login, select xosapp.

  11. Select OK.