Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA Enterprise SCADA

Modify the Olson time zone database

  • Last UpdatedApr 24, 2025
  • 1 minute read

To modify the Olson time zone database

  1. Update the %DataDir%\Shared\sdk\3rdParty\ZoneInfo\tzdata\ file.

    For example, to update the MST time offset from -7:00 to -10:00:

    1. Locate the config in C:\AVEVA\DNA\Shared\sdk\3rdParty\ZoneInfo\tzdata\northamerica.

    2. Change the offset value from -7:00 to -10:00 and save the file.

      For example:

      #Zone NAME STDOFF RULES FORMAT [UNTIL]

      Zone EST -5:00 - EST

      Zone MST -10:00 - MST

      Zone HST -10:00 - HST

  2. Open a Windows Command Prompt.

  3. Change the working directory to the %DataDir%\Shared\sdk\3rdParty\ZoneInfo\tzdata\ folder.

  4. Execute the zic.exe command to generate the updated time zone databases:

    <full path>\zic.exe -d ..\DB northamerica

    The output of the compilation is a set of binary data files, which are saved to the %DataDir%\Shared\sdk\3rdParty\ZoneInfo\DB\ folder.

    Note: Only the binary data files for northamerica files are updated.

  5. Follow the instructions in Deploy the Olson time zone database to deploy the Olson time zone database to all servers.