Override Process Monitor settings (example)

  • Last UpdatedApr 24, 2025
  • 1 minute read

Note: For information on overriding default configuration settings, refer to Modifying Configuration Settings.

The procedure below illustrates how to override the following settings in PubSub Engine (PSEngine)—a process within the Common product—to achieve behavior customized to your needs:

  • critical

  • processHandleCritical

  • processHandleWarning

To override Process Monitor settings for PSEngine

  1. In the %DNADataRoot%\Common\config\Settings directory, create a file named ProcessOverrideForPsEngine.json.

    The file name is arbitrary. In this example, we choose ProcessOverrideForPsEngine.json.

  2. Add the following content to the file:

    {

    "processMonitor": {

    "processes": {

    "psengine": {

    "critical": false,

    "processHandleCritical": 31001,

    "processHandleWarning": 20000

    }

    }

    }

    }

  3. Save the file.

  4. Restart the Common service to apply the changes to the settings for PSEngine.