AVEVA Enterprise SCADA

Create a Decode Define for the upload of hourly meter history

Create a Decode Define for the upload of hourly meter history

  • Last UpdatedApr 24, 2025
  • 2 minute read

Follow this procedure to create a Decode Define for the upload of Hourly Meter history.

To create a Decode Define for the upload of hourly meter history

  1. Open the Data Payload Processor (DPP) Config Tool window (refer to Open the Data Payload Processor (DPP) Config Tool window).

    Embedded Image (65% Scaling) (LIVE)

  2. Select the Decode Define tab.

    Embedded Image (65% Scaling) (LIVE)

  3. Select New > New Decode Define.

    The New Decode Define dialog box opens.

  4. In the Decode Name field, enter Xmodbus Upload Meter Hourly - Accum.

  5. In the Decode Description field, enter Xmodbus Upload Meter Hourly - Accum.

  6. In the Decode Definition field, enter the following:

    <source><proto><name>XMODBUS</name><command>Upload Meter Hourly History</command><load>XMODBUS_ACCUM</load><DPPLoadType>LoadType</DPPLoadType></proto></source>

    Note: Ensure that the <DPPloadType> value matches the value entered in the DPPLoadType field in the XMODBUS_ACCUM template on the Configurable Gas Load (CGL) Editor. For further information, refer to Configuring the Upload of Hourly Meter History for Accumulators.

  7. In the Add Templates section, select Xmodbus Upload Accum Hourly History and select Add.

  8. Select Save.

  9. Back on the DPP Config Tool window, select Refresh.

    The new Decode Define should now appear in the Decode Define tab of the DPP Config Tool window.