AVEVA Enterprise SCADA

Execute the set_fkeysXML stored procedure

  • Last UpdatedApr 24, 2025
  • 1 minute read

This stored procedure will list information about the foreign keys of a table within a database. The Microsoft SQL wildcard character % may be used to specify any of the input arguments. The output is in XML format.

Note: The specification of wildcard inputs to this call may return a massive stream of XML. Use with caution.

ODBC Syntax

call sp_fkeysXML(<database>, <table>, <key>)

Example

call sp_fkeysXML('RTDB', 'message', '%');

<?xml version="1.0" standalone="no"?>

<SQLEngineDatastoreSchema>

<database name="RTDB" owner="dbo">

<table name="message" owner="dbo" description="Message text and color"

allowUpdate="yes" allowSelect="yes" allowDelete="yes" allowInsert="yes"

tablelastmodified="10/10/2013 10:01:27.731" permissionslastmodified="10/10/2013

10:01:27.731">

<key primarykey="" primarydatabase="RTDB"

primaryowner="dbo" primarytable="message" primarycolumn="name" sequence="1"

foreignkey="" foreigndatabase="" foreignowner="" foreigntable="" foreigncolumn=""

updaterule="" deleterule=""/>

<key primarykey="" primarydatabase="EnumDB"

primaryowner="dbo" primarytable="pntcolor" primarycolumn="edescr" sequence="1"

foreignkey="" foreigndatabase="RTDB" foreignowner="dbo" foreigntable="message"

foreigncolumn="fg" updaterule="" deleterule=""/>

<key primarykey="" primarydatabase="EnumDB"

primaryowner="dbo" primarytable="sev_enum" primarycolumn="edescr" sequence="1"

foreignkey="" foreigndatabase="RTDB" foreignowner="dbo" foreigntable="message"

foreigncolumn="severity" updaterule="" deleterule=""/>

</table>

</database>