The node table is used by the Batch Tracking application. The records in the node table represent junctions, stations, or terminals in the pipeline. The node table contains the following internal fields:

Internal Field Name

Data Type

Description

alm_ena

oas_boolean_t

Enable the batch Estimated Time of Arrival (ETA) alarm?

alm_thres_t

long

The batch ETA time threshold (in minutes).

alm_thres_v

double

The batch ETA volume threshold.

anm_alm_ena

oas_boolean_t

Generate an alarm when the anomaly is received by the specified node?

anm_alm_thres_t

long

The anomaly ETA time threshold (in minutes).

anm_alm_thres_v

double

The anomaly ETA volume threshold.

anm_evt_ena

oas_boolean_t

Enable anomaly ETA events? The use of this field has been discontinued. The system will now always generate ETA events.

bdmerge_anm_ena

oas_boolean_t

Enable bad merge anomaly?

dataset

doas_dset_slot

This field indicates the dataset to which the record is assigned. Datasets are used to associate the record with the privileges assigned for each system mode. Once a record is assigned to a dataset value, the dataset can only be changed to a value for which the system has a privilege record.

etacalc

oas_boolean_t

Disable Estimated Time of Arrival (ETA) calculation?

dispname

pntname

Alternate name to be used on displays.

flag

flags

For information on the flag structure, see Flag structure details.

group

groupslot

This field shows the group that this point is associated with for alarming.

merge_anm_ena

oas_boolean_t

Enable merge anomaly?

name

pntname

The name of the node.

station

stationslot

The name of the associated station record.