AVEVA Enterprise SCADA

Initiate the modem_test process

  • Last UpdatedApr 24, 2025
  • 1 minute read

The modem_test process can be initiated by a command or through the Modem Control dialog box in easy eXtended Operator Station (ezXOS).

Note: The -m and -b options are mutually exclusive, but one must be set. If neither of these options is specified, the modem_test process is run against all the modems in the Modem table.

The modem_test process can be initiated in the following three ways:

  • fnput mode.modem_name TEST

    This command calls modem-test -m modem_name -1

  • fnput mbank.bank_name TEST [telno]

    This command calls modem-test -b bank_name -w5 -t[telno]. If [telno] is not provided, it defaults to -1 for local test mode.

  • Click Test Modem on the Modem Control dialog box. For more information, refer to the AVEVA Enterprise SCADA HMI Controller documentation.