Pipeline table details
- Last UpdatedApr 24, 2025
- 4 minute read
In the Batch Tracking application, the pipeline table is the primary table. Other records in the application have child relationships with pipeline records. The pipeline table contains the following internal fields:
|
Internal Field Name |
Data Type |
Description |
|---|---|---|
|
active |
oas_boolean_t |
Process the pipeline? |
|
basePress |
double |
The pressure to be used for volume corrections to Gross Standard Volume (GSV) if no analog input for pressure exists. |
|
baseTemp |
double |
The temperature to be used for volume corrections to GSV if no analog input for temperature exists. |
|
baseTempMonthly.baseTemp_select[0-11].baseTemp |
double |
The monthly temperatures to use for volume corrections to GSV if no analog input for temperature exists. |
|
baseTempMonthly.baseTemp_select[0-11].selected |
oas_boolean_t |
Use this temperature for volume corrections to GSV if no analog input for temperature exists? |
|
bdVolThrsh |
double |
The batch destination volume threshold for the record. |
|
dataset |
doas_dset_slot |
This field indicates the dataset to which the record is assigned. Datasets are used to associate the record with the privileges assigned for each system mode. Once a record is assigned to a dataset value, the dataset can only be changed to a value for which the system has a privilege record. |
|
delta_lp_filt |
double |
The linepack filtering coefficient. |
|
deltalpack |
double |
Delta linepack = current cycle linepack - previous cycle linepack. |
|
description |
description |
Description of the pipeline record, up to 47 characters in length. |
|
doBatchDest |
oas_boolean_t |
Should a batch destination check be performed? |
|
doing_write |
oas_boolean_t |
Is write in progress? |
|
enable_BTM |
oas_boolean_t |
Use monthly base temperatures rather than the single universal one? |
|
etaDeleteInterval |
int |
Defines when the Estimated Time of Arrivals (ETAs) that are past station can be deleted. |
|
fc |
double |
The proportional control value for the pipeline record. |
|
flag |
flags |
For information on the flag structure, see Flag structure details. |
|
force_lp_calc |
oas_boolean_t |
Should linepack calculations be performed even if the pipeline is disabled? |
|
gconv |
double |
The ground temperature convergence value for the record. |
|
group |
groupslot |
This field shows the group that this point is associated with for alarming. |
|
inactlim |
long |
The inactive alarm limit. |
|
isLinePackConfigInvalid |
oas_boolean_t |
Indicates whether or not the linepack configuration for the pipeline record is invalid. |
|
lastactive |
long |
The last time the pipeline was active. |
|
lastchange |
long |
The last time the pipeline status changed. |
|
lastrun |
long |
The last time Batch Tracking (BT) calculations were performed. |
|
linear |
oas_boolean_t |
Should linear interpolation be used? |
|
linepack |
double |
Current cycle linepack. |
|
lpack |
lpackalg |
The linepack algorithm selection. |
|
lock_stat |
int |
The pipeline lock status. |
|
multistateFlowForward |
string80 |
Comma-separated set of states representing forward in a multistate representing a flow. |
|
multistateFlowReverse |
string80 |
Comma-separated set of states representing reverse in a multistate representing a flow. |
|
multistateMixerOff |
string80 |
Comma-separated set of states representing off in a multistate representing a mixer. |
|
multistateMixerOn |
string80 |
Comma-separated set of states representing on in a multistate representing a mixer. |
|
multistatePumpOff |
string80 |
Comma-separated set of states representing off in a multistate representing a pump. |
|
multistatePumpOn |
string80 |
Comma-separated set of states representing on in a multistate representing a pump. |
|
multistateValveClosed |
string80 |
Comma-separated set of states representing closed in a multistate representing a valve. |
|
multistateValveOpen |
string80 |
Comma-separated set of states representing open in a multistate representing a valve. |
|
name |
pntname |
The unique name of this pipeline record. |
|
niter |
int |
The number of iterations to perform on the pipeline record. |
|
pconv |
double |
The convergence pressure value at pipe merge. |
|
pending_write |
int |
Pending write locks on the record. |
|
presthresh |
double |
Pressure threshold for the pipeline Maximum Operating Pressure (MOP) value. |
|
prevlpack |
double |
Previous cycle linepack. |
|
prevtohlpack |
double |
Previous Top of Hour (TOH) linepack. |
|
ptnum |
slot |
The slot number of the point in the database. |
|
pointClass |
configenumslot |
The point class category contains multiple configuration enumerations used for categorical configuration of points. |
|
pointSubClass |
configenumslot |
The point subclass category is a configurable enumeration category used for categorical configurations. It cannot be used for configurable alarms and events. |
|
safe_read |
int |
The safe read locks for the record. |
|
shutthresh |
double |
Shut-in flow rate threshold value for the pipeline record. |
|
statusFlowForward |
string80 |
Comma-separated set of states representing forward in a status representing a flow. |
|
statusFlowReverse |
string80 |
Comma-separated set of states representing reverse in a status representing a flow. |
|
statusMixerOff |
string80 |
Comma-separated set of states representing off in a status representing a mixer. |
|
statusMixerOn |
string80 |
Comma-separated set of states representing on in a status representing a mixer. |
|
statusPumpOff |
string80 |
Comma-separated set of states representing off in a status representing a pump. |
|
statusPumpOn |
string80 |
Comma-separated set of states representing on in a status representing a pump. |
|
statusValveClosed |
string80 |
Comma-separated set of states representing closed in a status representing a valve. |
|
statusValveOpen |
string80 |
Comma-separated set of states representing open in a status representing a valve. |
|
tf |
double |
The temperature tuning factor for the record. |
|
tohdeltalpack |
double |
Hourly delta linepack = Top of Hour linepack - previous Top of Hour linepack. |
|
tohlinepack |
double |
Top of Hour linepack. |
|
ts |
double |
The shut in filter value for the pipeline record. |
|
unitset_num |
unitset |
The unit set of the pipeline. |
|
mass |
double |
Current cycle mass. |
|
prevmass |
double |
Previous cycle mass. |
|
deltamass |
double |
Delta mass = current cycle mass – previous cycle mass. |
|
tohmass |
double |
Top of Hour (TOH) mass. |
|
prevtohmass |
double |
Previous Top of Hour mass. |
|
tohdeltamass |
double |
Hourly delta mass = Top of Hour mass – previous top of hour mass. |