Install the Datapump configuration
- Last UpdatedApr 24, 2025
- 1 minute read
Run the install tool from the Test and Development System where the files are under source control. Doing so will decrease the risk of loading an obsolete file.
Notes: You should only perform the following procedure after completing all Datapump configuration
(refer to Configure Datapump using the SAMPLE directory).
After upgrading a database to a newer version of a Data-tier Application Package (DACPAC),
you should reinstall Datapump on the upgraded database.
To install the Datapump configuration
-
Run SQLInstallTool.exe, and ensure that there are no red highlights.
-
Collapse all directories.
-
Install all files for each system.
Note: You will need to do this every time you change file. When it goes live (at minimum on the Test and Development System), make sure that you have no errors.
-
(Optional) If the system has an availability group installed, execute the following Datapump script to create a Microsoft SQL job on each secondary node dataserver:
%DataDir%\Historical\config\applicationsql\Datapump\DP_Populate_keys\TimeSeries\XIS_TIMESERIES_SQLJOBS_datapump.sql