Source Data Access Layer (DAL) file
- Last UpdatedApr 24, 2025
- 1 minute read
The following parameters in the source Data Access Layer (DAL) file are configurable:
-
DriverAlias โ Custom text to identify the target in the Advanced Database Editor (ADE) Pivot and Transfer dropdown menu
-
DriverProperty ConnectionString Host โ <TargetSystemRealTime> (for example, ls1pdcRealTime)
-
DriverProperty HostName โ <TargetSystemRealTime> (for example, ls1pdcRealTime)
-
An appropriate source DAL filename can be chosen as needed.
Example DALConfig_PnT_SameDomain_PDC.xml Source DAL File
<?xml version="1.0" encoding="UTF-8"?>
<DALConfig xmlns="http://www.telvent.com/DALConfig" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.telvent.com/DALConfig DALConfig.xsd">
<DriverAlias Alias="TARGET-SAMEDOMAIN-PDC">
<DriverType Type="DBEdit">
<Description>RealTime DBEdit Driver</Description>
<DriverLocator>OASySDNA.Common.DAL.DBEdit777Driver.dll</DriverLocator>
<TransportType>InProcess</TransportType>
<DriverProperty Name="NumConnections">1</DriverProperty>
<DriverProperty Name="ConnectionString">Driver=DataDirect OpenAccess SDK
8.1;UID=%Username%;PWD=%Password%;Port=19990;Host=ls1pdcRealtime;DefaultDB=RTDB;SDSN=SQLEngine_%SQLAuthenticationType%;SCHEMA=ANSI;CLIENTHOSTNAME=%ClientHostName%;TIMEZONE=%TimeZone%;AppName=%ClientAppName%</DriverProperty>
<DriverProperty Name="DBProviderType">System.Data.Odbc</DriverProperty>
<DriverProperty Name="DBName">RTDB</DriverProperty>
</DriverType>
<DriverType Type="BLT">
<Description>RealTime BLT Driver</Description>
<DriverLocator>OASySDNA.Common.DAL.BLT75Driver.dll</DriverLocator>
<TransportType>InProcess</TransportType>
<DriverProperty Name="HostName">ls1pdcRealtime</DriverProperty>
<DriverProperty Name="NumOfThreads">1</DriverProperty>
<DriverProperty Name="LocaleID">%LocaleID%</DriverProperty>
<DriverProperty Name="TimeZone">%TimeZone%</DriverProperty>
<DriverProperty Name="TablePollMultiplier">1</DriverProperty>
</DriverType>
</DriverAlias>