Configure the integrity check interval

  • Last UpdatedApr 24, 2025
  • 1 minute read

Periodically, StationRollup checks the integrity of the internal cache against the RealTime database (RTDB). Follow the procedure below to configure the interval at which StationRollup carries out the task.

Notes: The minimum value is one minute.

Higher values slightly decrease the load on the system, where a higher timeout would result in the cache being out of sync for a longer period of time.

To configure the integrity check interval

  1. In the %DNADataRoot%\RealTime\Service\config\Settings directory, either create or open the RealTime_DataExport_StationRollup.json file.

  2. In the StationRollupPlugin object, change the StationRollupCacheIntegrityTimeout key to the desired value.

    {

    "RealTime": {

    "DataExport": {

    "Plugins": {

    "StationRollupPlugin": {

    "StationRollupCacheIntegrityTimeout": "00:05:00"

    }

    }

    }

    }

    }