Create a Decode Template for the upload of hourly Gas Quality (GQ) history from meter history
Follow this procedure to create a Decode Template for the Upload of Hourly Gas Quality (GQ) History from Meter history.
To create a decode template for the upload of hourly Gas Quality (GQ) history from meter history
-
Open the Data Payload Processor (DPP) Config Tool window (refer to Open the Data Payload Processor (DPP) Config Tool window).

-
Select the Template Define tab.

-
Select New > New Decode Template.
The New Decode Template dialog box opens.

-
In the Template Name field, enter Xmodbus Upload GQ hourly from Meter History - Consecutive Array.
-
In the Template Description field, enter Xmodbus Upload GQ hourly from Meter History - Consecutive Array.
-
In the Stored Procedure field, select Hourly Gas Analysis.
-
Select Save.
The following occurs:
-
DPP generates a list of all the usable parameters in Decode Method format for the procedure selected in Step 6.
-
The Decode Method Template dialog box opens with these generated parameters.

-
-
Following the manufacturer's user documentation on the Consecutive Array protocol reply message, configure each parameter as required.