Accessing AVEVA Enterprise SCADA Net Configuration Data Store

Accessing AVEVA Enterprise SCADA Net Configuration Data Store

  • Last UpdatedJan 22, 2021
  • 1 minute read

The AVEVA Enterprise SCADA Net Configuration Data Store is used to store system-wide information on security, host names, and other information. It resides in Active Directory Lightweight Directory Services (AD LDS)

About this task

To access it from your component, you add a reference to OASySDNA.Common.

To access AVEVA Enterprise SCADA Net Configuration Data Store

  1. Click View > Solution Explorer.

  2. Expand your project until you see the References item.

  3. Right-click References, and select Add Reference.

  4. Go to the .NET tab, and double-click on OASySDNA.Common.

  5. Click OK.

  6. Go to the <name>Processor file and add the following line at the top: using OASySDNA.Common.Config;

    Note: The following example gets the virtual host name of the RealTime service.

    OASySDNA.Common.Config.DNAService dnaService = new DNAService();dnaService.Attach("MYSYSTEM","Realtime");string szRealtimeHost = dnaService.GetVirtualHostName();