Follow the procedure below to print host names in the bad host list to the oasErrLog.log file.
To view hosts on the bad hosts list
-
On the desktop, double-click the Windows PowerShell for DNA shortcut.
Windows PowerShell for DNA opens.
-
Execute the following commands:
set-silo RealTime
fnput omnicomm.<omnicomm name> dumpbadhostlist
Note: The dumpbadhostlist part of the command is not case-sensitive.
-
View the output in the oasErrLog.log file.
Sample bad host listing in the oasErrLog.log file:
2018-06-29 13:28:38.257 OMNICOMM LMSOmni 5108 [TID=0x14cc] - OMNICOMM "LMSOmni":
Following hosts were non-responsive and thus skipped for the indicated # of requests:
Host "qasim5x" reqested 77960 times. {omniutil.cpp:123}
In the above example, the section "reqested (sic) 77960 times" indicates the total number of times that Omnicomm skipped a connection attempt because the device was on the bad host list.