SpoolMsg

  • Last UpdatedJul 05, 2024
  • 1 minute read

The function of this Business Logic Tier (BLT) is to spool a message to a spooler. The RealTime database (RTDB) must be open before calling SpoolMsg. You can use VDB.OpenDatabase() to open the RTDB.

Syntax

SpoolMsg <spooler> <time> <msec> <type> <host> <process> <dbName> <ptname> <description> <rtu> <group> <message> <severity> <color>

 

Parameters 

Name

Description

spooler

The spooler to which the message is directed.

time

The timestamp for the spooler message.

msec

The millisecond value of the timestamp.

type

The type of message. This can be any of the following: alarm, control, event, or Sequence of Events (SOE).

host

The name of the host where the message came from.

process

The name of the process generating the message.

dbName

The RTDB table name or "" if there is none.

ptName

The RTDB point name or "" if there is none.

description

The long description of the point, or "".

rtu

The name of the remote at which the point is located or "".

group

The group name of the point, or "".

message

The text of the message to be spooled.

severity

The message priority.

color

The alarm color (for future use).

 

Example

To spool a test event message:

SpoolMsg 1,0,0, "event", "OASXIS1", "","","","","","group1","a test event message", 1, "white"

Comments