Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA Enterprise SCADA

Gasquality table details

  • Last UpdatedApr 24, 2025
  • 2 minute read

Gasquality records are created and configured in Measurement. Only fields specific to RealTime operation are available for editing in the Advanced Database Editor (ADE). The table is initially populated via AVEVA Measurement Advisor. The gasquality table contains the following internal fields:

Internal Field Name

Data Type

Description

dataset

doas_dset_slot

This field indicates the dataset to which the record is assigned. Datasets are used to associate the record with the privileges assigned for each system mode. Once a record is assigned to a dataset value, the dataset can only be changed to a value for which the system has a privilege record.

DataSource

GasQ_DataSource

The gas quality type.

description

description

A description of this gasquality point, up to 47 characters in length.

dnldRTAnalysis

oas_boolean_t

Download RealTime analysis?

failedLastConfiguration

oas_boolean_t

Did the last calculation fail from configuration?

failedLastSetpointLimit

oas_boolean_t

Did the last calculation fail from setpoint limit?

flag

flags

For information on the flag structure, see Flag structure details.

group

groupslot

This field shows the group that this point is associated with for alarming.

name

pntname

The unique name of this gasquality record. The name can be up to 32 characters in length.

redirect

oas_boolean_t

Enable or disable gas composition redirects.

redirectSource

gasqualityslot

The source for gas composition redirects.

rtu

remoteslot

The remote associated with this gas meter.

setpointLimits

Setpoint_Array

The Array of setpoint limits to determine if Virtual Chromatograph data will be downloaded.

setpointLimitsAlminh

oas_boolean_t

Inhibit alarms associated with setpoint limits?

streamNumber

short

The Stream number for the gas quality (GQ).

virtChrom

vc_sources

The RealTime source of virtual data used in a weighted average calculation.

virtualChromEnable

oas_boolean_t

Enable or disable Virtual Chromatograph calculations.