Rts_cleanup​.csc

  • Last UpdatedJul 05, 2024
  • 1 minute read

Manual data cleanup can also be done using rts_cleanup.csc.

The process is started by executing rts_cleanup.csc on the RealTime computer. This locates the primary Archive service host (if not specified with the -A parameter) and executes the Cleanup Business Logic Tier (BLT) on that host. The syntax is:

rts_cleanup.csc [-h] [-A archive_host][options]

Where:

-h displays usage information.

-A specifies a optional host name on which to force the command to run. If a host is not specified, the primary Archive service host for the local system is used.

Note: The (JSH) is normally configured to run rts_cleanup.csc once per day after rts_archive.csc has already run.

rts_cleanup options

Options

Description

-T <dbName>

This parameter specifies the name of the database in the archive schedule.

-t <tableName>

This parameter specifies the name of the table in the archive schedule.

-b <batch size>

This parameter specifies the maximum number of rows to be deleted per transaction. The default is 1000.