Enter the results of Point to Point Verification
- Last UpdatedApr 24, 2025
- 3 minute read
Perform this procedure to check if the value of a point displayed in AVEVA Enterprise SCADA differs from the value recorded by the field instrument.
Before you begin
Complete the steps in Open the Point Verification Control dialog box.
-
Configure the various fields on the Point Verification Control dialog box, using the table below as a guide.
-
Do one of the following:
-
To save the record in a pending state, refer to Create a pending record.
-
To submit the record, refer to Save verification information to the database.

Item
Description
Address
The point's input/output coordinates.
As noted above, you must configure this field for multistate points.
Verified
This field indicates whether or not the data currently displayed on the Point Verification Control dialog box exists in the CRM database in a "verified" state.
Verification Reason
The reason for verification.
Options:
-
Display Change
-
SCADA Database Change
-
PLC/RTU Field Device Change
-
Initial Commissioning
Verification Date
One of the following:
-
The date on, and local time at, which point verification results for the record were last submitted to the CRM database.
-
Today's date and the current, local time after you select New to enter new results.
Note: In the event of a change to the time zone setting, the new setting only takes effect after the restart of the easy eXtended Operator Station (ezXOS).
Field Location
The name of the associated station (station record).
Equipment Description
The record's point class.
Physical Location
The physical location of the point.
Phys. Loc. Verified By
The name* of the person who verified the Physical Location.
SCADA Value
The point's current value.
Recorded SCADA Value
Select Capture to copy the point's current value from the SCADA Value field into one of the three Recorded SCADA Value fields. Modify the value as desired.
When you verify the record, the application saves the Recorded SCADA Value field values to the CRM database.
Field Value
Record the current field value into one of the three Field Value fields to correspond with the Recorded SCADA Value fields.
Commanded
Select this check box if verification is done by issuing a command to the field device.
Feedback
Select this check box if verification is done using a feedback point in the field device.
Scaled Value
Select this check box if the Field Value uses a different scaling value from the SCADA Value.
Calibration
Select this check box if commissioning is being performed during a calibration task. Selecting this check box enables the "As Found" Value and "As Left" Value fields.
Simulated
Select this check box if some method other than reading the actual value is used to perform the test.
Simulation Reason
Record the reason for simulating the SCADA Value.
"As Found" Value
The current value of the point prior to calibration.
"As Left" Value
The current value of the point after calibration.
SCADA Verified
The name of the user logged on to the system.
Field Verified
The name* of the person responsible for retrieving the field value entered in the Field Value field.
Approved By
The name* of the person who approved the Field Value.
Safety Point
This field indicates whether or not the point is safety related.
For further information, refer to Safety points.
Alarms Test Method
A brief description of the method used to test alarms on this point.
MOC #
The number of the maintenance system containing commissioning or calibration information.
Reference #
The reference number associated with this verification record.
Comments
Comments about this verification record.
Remove From Test Mode Sets
If selected when Verify is selected, then the point that is being verified will be automatically removed from any test mode sets that it is contained in, and the point is taken out of test mode.
*Any available names in the Phys. Loc. Verified By, Field Verified, and Approved By fields come from the On Call database if your system is configured with the On Call database. Any name can be entered into these fields regardless of what names appear in the dropdown menu. For further information, refer to On Call.
Note: The names are stored independent of the On Call database. If, for example, an employee leaves the company, an Administrator will likely remove his name from the On Call database. The former employee's name, however, remains attached to the results submitted to the CRM database.
-
-