AVEVA Enterprise SCADA

Helpdb

  • Last UpdatedJul 05, 2024
  • 1 minute read

The function of this Business Logic Tier (BLT) is to display information on all RealTime database (RTDB) tables, or for a particular RTDB table.

The data returned for each table includes the following information:

  • Point count

  • Table dimension

  • Whether or not data export is enabled (1 for enabled; 0 for disabled)

  • Whether or not double buffering is enabled (1 for enabled; 0 for disabled)

Syntax

helpdb {table_name]

Parameters

Name

Description

table_name

Information on the RTDB table, which is specified by this parameter, is displayed. If table_name is not given, a report on all RTDB tables is returned.

Example

Helpdb analog

Name

Points

Data

Overhead

%Data

Dimension

Data Export

Double Buffering

analog

7845

3772440

1590472

70.343127

8000

1

0

In This Topic