FlowTotalConfig table details
- Last UpdatedApr 24, 2025
- 4 minute read
The flowTotalConfig table is used to store point totals and calculation elements used by the Flow Total application. The flowTotalConfig table contains the following internal fields:
|
Internal Field Name |
Data Type |
Description |
|---|---|---|
|
accessFlag |
varchar |
The display accessing this record. |
|
activeAlmLimit_[0-3] |
varchar |
The associated active alarm limit for totalBlock[0-3], respectively. |
|
almLimitSet[0-3] |
almlimitsetslot |
The name of the almlimitset record that uses the alternative alarm limits configured in the almlimit record. |
|
dataset |
doas_dset_slot |
This field indicates the dataset to which the record is assigned. Datasets are used to associate the record with the privileges assigned for each system mode. Once a record is assigned to a dataset value, the dataset can only be changed to a value for which the system has a privilege record. |
|
description |
description |
A description of this flowTotalConfig point, up to 47 characters in length. |
|
displayOrder |
int |
The display order of the record. |
|
dsysControl |
varchar |
Indicates if the local system is in control of this remote. |
|
enabled |
oas_boolean_t |
Have the Monitor process calculate values for the flowTotalConfig record's associated elements? |
|
flag |
flags |
For information on the flag structure, see Flag structure details. |
|
group |
groupslot |
This field shows the group that this point is associated with for alarming. |
|
lastTime |
int |
The last time the record was krunched. |
|
lastTime.high |
int |
The last time the record was krunched (displayed in high order by seconds). |
|
lastTime.low |
int |
The last time the record was krunched (displayed in low order by milliseconds). |
|
mappingFlag |
unsigned int |
The 32-bit integer value used to map this point to a non-AVEVA Enterprise SCADA system. |
|
name |
pntname |
The unique name of this flowTotalConfig record. The name can be up to 32 characters in length. |
|
pointClass |
configenumslot |
The Point Class category contains multiple configuration enumerations used for categorical configuration of points. |
|
pointSubClass |
configenumslot |
Point Sub Class is a configurable enumeration category used for categorical configurations, but you cannot use this for configurable alarms and events. |
|
priority |
exec_order |
The priority of calculation (execution order) of the flowTotalConfig record. |
|
ptnum |
int |
The slot number in the database. |
|
safetyPtState[0-49].Condition |
varchar |
The safety condition of the state. |
|
stateInhibit.inh_dev |
oas_boolean_t |
Inhibit Creep state alarming? |
|
stateInhibit.inh_flat |
oas_boolean_t |
Inhibit Flatline state alarming? |
|
stateInhibit.inh_hi |
oas_boolean_t |
Inhibit High state alarming? |
|
stateInhibit.inh_hihi |
oas_boolean_t |
Inhibit HighHigh state alarming? |
|
stateInhibit.inh_lo |
oas_boolean_t |
Inhibit Low state alarming? |
|
stateInhibit.inh_lolo |
oas_boolean_t |
Inhibit LowLow state alarming? |
|
stateInhibit.inh_roc |
oas_boolean_t |
Inhibit Rate of Change state alarming? |
|
stateInhibit.inh_uhi |
oas_boolean_t |
Inhibit User High state alarming? |
|
stateInhibit.inh_ulo |
oas_boolean_t |
Inhibit User Low state alarming? |
|
station |
stationslot |
The name of the associated station record. |
|
totalBlocks.totalBlock[0-3].ana_rate |
analogslot |
The name of the analog record used as a rate in the Offscan Integration equation. |
|
totalBlocks.totalBlock[0-3].avg.doit |
oas_boolean_t |
Have the Monitor process calculate the average value for the element? |
|
totalBlocks.totalBlock[0-3].creep.devlim |
float |
The maximum deviation value (EGUs) that is acceptable before calibration deteriorates. |
|
totalBlocks.totalBlock[0-3].creep.doit |
oas_boolean_t |
Enable Creep Detection alarming? |
|
totalBlocks.totalBlock[0-3].doTod |
oas_boolean_t |
Roll over the flowTotalConfig record at the totalBlocks[0-3].Tod hour? |
|
totalBlocks.totalBlock[0-3].enabled |
oas_boolean_t |
Enable calculation of this element's value? |
|
totalBlocks.totalBlock[0-3].engrunit.egumax |
float |
The highest measurable value of the instrument in engineering units (EGUs). |
|
totalBlocks.totalBlock[0-3].engrunit.egumin |
float |
The lowest measurable value of the instrument in EGUs. |
|
totalBlocks.totalBlock[0-3].flag.alminhconfig |
oas_boolean_t |
Inhibit off-normal alarming? |
|
totalBlocks.totalBlock[0-3].flag.cevinh |
oas_boolean_t |
Inhibit normal logging? |
|
totalBlocks.totalBlock[0-3].flag.clrinhconfig |
oas_boolean_t |
Inhibit normal alarming? |
|
totalBlocks.totalBlock[0-3].flag.evtinh |
oas_boolean_t |
Inhibit off-normal logging? |
|
totalBlocks.totalBlock[0-3].flag.priorityDisplay |
modelname |
The display associated with the Priority Display icon on an easy eXtended Operator Station (ezXOS) Control dialog. |
|
totalBlocks.totalBlock[0-3].flags.bsmg |
messageslot |
The message associated with the element. |
|
totalBlocks.totalBlock[0-3].hilow.dead |
float |
The alarm deadband value for the flowTotalConfig point. |
|
totalBlocks.totalBlock[0-3].hilow.deltatime |
long |
The time interval over which the system should calculate the Rate of Change (ROC). |
|
totalBlocks.totalBlock[0-3].hilow.doitflat |
oas_boolean_t |
Enable Flatline Alarming? |
|
totalBlocks.totalBlock[0-3].hilow.doithi |
oas_boolean_t |
Enable the High alarm limit? |
|
totalBlocks.totalBlock[0-3].hilow.doithihi |
oas_boolean_t |
Enable the HighHigh alarm limit? |
|
totalBlocks.totalBlock[0-3].hilow.doitlo |
oas_boolean_t |
Enable the Low alarm limit? |
|
totalBlocks.totalBlock[0-3].hilow.doitlolo |
oas_boolean_t |
Enable the LowLow alarm limit? |
|
totalBlocks.totalBlock[0-3].hilow.doitroc |
oas_boolean_t |
Enable ROC alarming? |
|
totalBlocks.totalBlock[0-3].hilow.doituhi |
oas_boolean_t |
Enable the user-defined High alarm limit? |
|
totalBlocks.totalBlock[0-3].hilow.doitulo |
oas_boolean_t |
Enable the user-defined Low alarm limit? |
|
totalBlocks.totalBlock[0-3].hilow.flattimeout |
unsigned short |
The maximum about of time (minutes) that can pass without the flowTotalConfig value changing. |
|
totalBlocks.totalBlock[0-3].hilow.hihilim |
float |
The HighHigh alarm limit for the flowTotalConfig point. |
|
totalBlocks.totalBlock[0-3].hilow.hilim |
float |
The High alarm limit for the flowTotalConfig point. |
|
totalBlocks.totalBlock[0-3].hilow.lolim |
float |
The Low alarm limit for the flowTotalConfig point. |
|
totalBlocks.totalBlock[0-3].hilow.lololim |
float |
The LowLow alarm limit for the flowTotalConfig point. |
|
totalBlocks.totalBlock[0-3].hilow.negroclim |
float |
The maximum, negative allowable ROC (EGUs per second). |
|
totalBlocks.totalBlock[0-3].hilow.roclim |
float |
The maximum, positive allowable ROC (EGUs per second). |
|
totalBlocks.totalBlock[0-3].hilow.roc_method_used |
ROC_method |
The type of ROC alarming to use. |
|
totalBlocks.totalBlock[0-3].hilow.uhi |
float |
The user-defined High alarm limit for the flowTotalConfig point. |
|
totalBlocks.totalBlocks[0-3].hilow.ulo |
float |
The user-defined Low alarm limit for the flowTotalConfig point. |
|
totalBlocks.totalBlocks[0-3].intg.doit |
oas_boolean_t |
Have the Monitor process calculate the total quantity (for example, volume) over a given time period? |
|
totalBlocks.totalBlocks[0-3].intg_enable |
oas_boolean_t |
Have the Monitor process calculate the total quantity when one of the associated data sources goes offscan? |
|
totalBlocks.totalBlocks[0-3].intg.scale |
float |
The factor used to scale the accumulated quantity. |
|
totalBlocks.totalBlocks[0-3].stateInhibit.inh_dev |
oas_boolean_t |
Inhibit Creep alarming? |
|
totalBlocks.totalBlocks[0-3].stateInhibit.inh_flat |
oas_boolean_t |
Inhibit Flatline alarming? |
|
totalBlocks.totalBlocks[0-3].stateInhibit.inh_hi |
oas_boolean_t |
Inhibit High alarming? |
|
totalBlocks.totalBlocks[0-3].stateInhibit.inh_hihi |
oas_boolean_t |
Inhibit HighHigh alarming? |
|
totalBlocks.totalBlocks[0-3].stateInhibit.inh_lo |
oas_boolean_t |
Inhibit Low alarming? |
|
totalBlocks.totalBlocks[0-3].stateInhibit.inh_lolo |
oas_boolean_t |
Inhibit LowLow alarming? |
|
totalBlocks.totalBlocks[0-3].stateInhibit.inh_roc |
oas_boolean_t |
Inhibit ROC alarming? |
|
totalBlocks.totalBlocks[0-3].stateInhibit.inh_uhi |
oas_boolean_t |
Inhibit User High alarming? |
|
totalBlocks.totalBlocks[0-3].stateInhibit.inh_ulo |
oas_boolean_t |
Inhibit User Low alarming? |
|
totalBlocks.totalBlocks[0-3].Tod |
int |
The hour of the day at which to roll over the flowTotalConfig record. |
|
totalBlocks.totalBlocks[0-3].unit |
units |
A text string that describes the EGUs that are measured by this point. |
|
useAlmLimitSet[0-3] |
oas_boolean_t |
Associate the flowTotalConfig point with alternative alarm limits? |
|
watchdog |
varchar |
The point staled by the Flatline Watchdog application. |
|
wellunit |
varchar |
The well unit name. |