The ProcedureAcceleratorListProcedures is an internal Business Logic Tier (BLT) that returns a list of Alarm Procedure records that match the supplied arguments. This BLT allows you to work with the alarm procedure records.

The table below details the input parameters for the ProcedureAcceleratorListProcedures BLT.

Argument

Description

Category

The category of the alarm to match.

Severity

The severity (low, minor, medium, major, high, critical) of the alarm to match.

PointName

The name of the point to match.

AlarmMessage

The message text of the alarm to match.

Mode

Alarm or Point

Alarm โ€” Only Alarm Procedures that match all arguments will be returned.

Point โ€” All Alarm Procedures that match the PointName will be returned. No other arguments will be checked.

Condition

NONE or SAFETY

The condition of the alarm to match.

The SAFETY condition depends on the Safety Point configuration (the Safety Related attribute or the condition of the alarm state) of the point related to the alarm.

The table below details the output parameters for the ProcedureAcceleratorListProcedures BLT.

Argument

Description

Result

The result code of the BLT execution โ€” zero on success, non-zero value on error

Message

If the result is a non-zero value, the message displayed will contain an error message indicating the source of the problem.

The table below details the results of the ProcedureAcceleratorListProcedures BLT.

Column

Description

Description

The description of the alarmProcedure record.

Url

The URL for the Alarm Procedure.

Slot

The ptnum of the alarmProcedure record.