Use this Row Edit dialog box to configure the basic settings of a trendIndicatorImageSet record.

The following table details the items on the Main Tab of the trendIndicatorImageSet Row Edit Dialog Box.

Items

Description

Name

Select (...), and select the name of the trendIndicatorImageSet record you want to edit from the Select dialog box, or enter a new trend indicator image set name to create a new record.

Description

Enter a description of the record. The description can be up to 47 characters in length. This field is for information purposes only and can be used to describe the record.

Input Table Name

A table name for telemetered records to which this set is applicable and limited to.

From the Input Field field, select (...) to edit both the Input Table Name and the Input Field using the Input Field Selector dialog box. For more information, refer to Input Field Selector.

Important: The Input Table Name field cannot be modified once the trendIndicatorImageSet record is created and saved. If you need to replace the input table name of the current record, you must duplicate the record by creating a copy of the current record, and then selecting a different input table name.

Note: Analog and rate tables are currently supported and configured by default as allowed input field tables.

Input Field

An input field whose value is used against the trend indicator set threshold ranges to determine the image representing the current trend indication. Select (...) to edit this value. For more information, refer to Input Field Selector.

Normal Image

The image used to indicate that the input value has not exceeded either of the defined thresholds.

Select (...), and select the icon you want to appear from the Image Selector dialog box.

Note: AVEVA Enterprise SCADA includes a preconfigured set of images that can be used for this feature. For further information, refer to the AVEVA Enterprise SCADA HMI Display Builder documentation.

Minor Increase Threshold

The value that delimits a minor increase range.

Minor Increase Image

The image used to represent the value of the Input Field relative to the defined minor increase threshold. Select (...) and select the icon you want to appear from the Image Selector dialog box.

Major Increase Threshold

The value that delimits a major increase range.

Major Increase Image

The image used to represent the value of the Input Field relative to the defined major increase threshold. Select (...), and select the icon you want to appear from the Image Selector dialog box.

Minor Decrease Threshold

The value that delimits a minor decrease range.

Minor Decrease Image

The image used to represent the value of the Input Field relative to the defined minor decrease threshold. Select (...), and select the icon you want to appear from the Image Selector dialog box.

Major Decrease Threshold

The value that delimits a major decrease range.

Major Decrease Image

The image used to represent the value of the Input Field relative to the defined fast decrease threshold. Select (...), and select the icon you want to appear from the Image Selector dialog box.