Test dial-out modems via modem_test

  • Last UpdatedApr 24, 2025
  • 1 minute read

The dial-out modem test process, modem_test, is run automatically according to the schedule defined in the Job Scheduler (jsh) table.

When run automatically, the modem_test process tests a specific modem, or all modems associated with the modem bank (Mbank) that are either available or out-of-service.

The modem-test process is used to test the availability of a modem, and whether or not it is responding to commands. This process is only available on non-cryout modems and modem banks.

Syntax

modem_test [-m modem_name][-b bank_name][-h][-w delay][-l]|-t telno]

mode-test options

Option and parameter

Description

-m

modem_name

If the -m option is specified and a valid modem name is given, the modem_test process is run against only that modem.

-m

modem_name

If the -b option is specified and a valid modem bank name is given, the modem_test process is run against all the modems in that bank.

-m

modem_name

This is the delay or wait-time between testing modems in a modem bank. This is expressed in seconds and is only valid with the -b option.

-m

modem_name

-l, which stands for local test mode, is the default mode. This mode tests with the phone number "*", which usually rings "busy" on most systems but detects a "no dialtone" structure (same as -t t*).

-m

modem_name

This mode gives a telephone number (telno), prefixed by t or p for tone or pulse, for use as the test number.

-m

modem_name

If the -h option is specified, the modem_test process displays the syntax/usage message.