Configurable Gas Load (CGL) templates vs. Remote Terminal Unit (RTU) loads
- Last UpdatedApr 24, 2025
- 1 minute read
The number of Configurable Gas Load (CGL) Templates you need to create depends on the number of Remote Terminal Unit (RTU) loads. For every RTU load, there must exist a unique CGL template associated with that load.
The following table illustrates this concept in relation to a hypothetical customer. In this example, the customer will require four unique CGL templates.
|
RTUs |
Load in RTU |
RTU Counts |
Number of Unique CGL Templates Required |
CGL Template Name (user-defined) |
|---|---|---|---|---|
|
Enron Modbus |
Load1 |
10 |
1 |
ENRON_MODB US |
|
BSAP 3330 |
Load1 |
50 |
1 |
BSAP_3330_LO AD1 |
|
BSAP 3330 |
Load2 |
20 |
1 |
BSAP_3330_LO AD2 |
|
Daniel Modbus |
Load1 |
20 |
1 |
DANIEL_MODB US |
Note: Identical data is available for RTUs that share the same load. Such RTUs are set up to process the same Historical data into the same Historical structure format for the same meter runs or chromatograph streams.