Verification of the Result
- Last UpdatedJan 18, 2023
- 1 minute read
The result from a Block Division is mainly checked by investigating the source and target block contents. If the blocks are of the same type and the target blocks match the cutters and cover the source block volume, the source block should be empty after a successful division.
If the source block is a Design block and the target blocks are Production blocks the Design panels remain. In this case every Design panel in the source block will get one or multiple corresponding Production panels. If the target blocks don't cover the whole volume of the source block the remaining Production panels will be placed in the default production block.
The names of the new panels are automatically derived form the original panel according to built-in rules. If the block name is part of the panel name it will be exchanged to the name of the target block.
It is also a good idea to use the Verify function to ensure that the new panels are ok.