  1. In the Status Controller select the rows for the objects to be controlled, right-click in the selected area, and click Edit Status.

  2. This will display the form to edit values of the Focus Status for the selected objects. Initially the objects are Not Controlled, that means, they have not been assigned a status value (for this status definition - they may have status values for other status definitions). Click on the drop-down list and select Assign to the initial value, enter a Comment (optional), and then click on OK or Apply.

  3. The available options for status values will then reflect the valid transitions in the status definition. For example, from Work Completed, there are two transitions.

  4. If Promote and Demote transitions have been defined, these can be selected directly.

    This will display a variant of the Edit Status window showing appropriate options.

    Note:
    Actual values will be shown if all selected objects share the same values, otherwise they will be displayed as mixed.

  5. The Remove Status option will delete the status data for the selected objects, so that they will no longer be controlled.

  6. The Navigate To option will be enabled for a single row selection and will set the current element.