Rectangular Components - Material Connection
- Last UpdatedJan 13, 2026
- 2 minute read
The task of creating an HVAC Component is initiated from the HVAC Window.
-
Select Rectangular in the Categories dropdown list and then Material Connection in the Available Type dropdown list to display the Material Connection window:

You are required to input the following dimensions:
-
Duct width AA
-
Duct depth AB
-
Overall length
-
Mat’l Thickness
-
Arrive Slipover
-
Leave Slipover
-
-
To visualize how the dimensions equate to the actual piece of HVAC, select Picture to display a detailed drawing for Rectangular Components Catalog Element - Material Connection.
Note: The fields will be pre-populated with default dimension. These dimension are governed by the details defined in the HVAC Catalog.
-
Select Transpose width/depth to exchange Duct Width AA dimension with Duct depth AB dimension.
-
Specify a type of joint to use for the Arrjoint (Arrive Joint) and Leajoint (Leave Joint). Use this type of joint for the inlet side of the component. For a detailed description, see Create / Modify HVAC Components.
-
After selecting the type of joint to use for the Arrjoint and Leajoint, enter the Width Direction.
-
In the Width Direction specify the axis to be used. Valid axes are E (East), N (North), U (Up), -E (negative East), -N (negative North) or -U (Negative Up).X, Y, Z, -X, -Y or -Z.
-
In the Connect list, select Connect or Unchanged:
-
Select Connect (default when Create is selected) - connects the piece of HVAC to the previous one.
-
Select Unchanged (default when Modify is selected) - positions the component at the co-ordinates 0.00.
Note: Unchanged is usually used, when Modify is selected, it does not connect the component but positions it at 0.00, in effect in a floating position.
-
-
Select Defaults to reset all the fields back to when the Material Connection window was opened.
-
Select Fit to orientate the Material Connection to automatically match the outlet (p-leave) of the previous piece of HVAC to the inlet (p-arrive) of the next piece.
-
Select OK to create the Material Connection component and close the Material Connection Window. You will be returned to the HVAC Window.
-
Select Cancel to discard all field changes and close the Material Connection window.