Hull and Outfitting

Joint Start and End References

  • Last UpdatedNov 18, 2025
  • 1 minute read

Keywords:

JOISTART JOIEND

Description:

Section ends which have been connected in the structure have their JOIS (Joint Start) and JOIE (Joint End) attributes set such that they cross-refer to the Joints to which those ends are connected. (The Joints have a similar cross-reference, the CREF attribute, back to the attached Section.)

These attributes are set automatically when a Section is connected and you will not usually need to set them specifically.

Example:

JOIE /PJOI.RB.2

Sets logical connection from Section’s end to named Primary Joint.

Command Syntax:

>--+-- JOIStart --.
   |              |
   ‘-- JOIEnd ----+-- <gid> -->

Querying:

Q JOIStart

Q JOIEnd