Rectangular Components - Internal Damper

  • Last UpdatedJan 13, 2026
  • 2 minute read

The task of creating an HVAC Component is initiated from the HVAC Window.

  1. Select Rectangular in the Categories drop-down list and then Internal Damper in the Available Type drop-down list to display the Internal Damper window:

    You are required to input the following dimensions:

    • Duct width AA

    • Duct depth AB

    • Dist from Leave

      Note: The fields will be pre-populated with default dimensions. These dimensions are governed by the details defined in the HVAC Catalog.

  2. To visualize how the dimensions equate to the actual piece of HVAC select Picture to display a detailed drawing for Rectangular Components Catalog Element - Internal Damper.

  3. Select Transpose width/dept to exchange the Duct width AA dimension with Duct depth AB dimension.

  4. In Handle Direction specify the axis to be used. Valid axes are E (East), N (North), U (Up), -E (negative East), -N (negative North) or -U (Negative Up).X, Y, Z, -X, -Y or -Z.

  5. The Clash Vol fields will be pre-populated with the obstruction volumes associated with the access panel and the ducting, but can be changed.

  6. In the Connect list, select Connect or Unchanged:

    • Select Connect (default when Create is selected) - connects the piece of HVAC to the previous one.

    • Select Unchanged (default when Modify is selected) - positions the component at the co-ordinates 0.00.

    Note: Unchanged is usually used, when Modify is selected, it does not connect the component but positions it at 0.00, in effect in a floating position.

  7. Select Defaults to reset all the fields back to when the Internal Damper window was opened.

  8. Select Fit To Next to orientate the Internal Damper to automatically match the outlet (p-leave) of the previous piece of HVAC to the inlet (p-arrive) of the next piece.

  9. Select OK to create the Internal Damper component and close the Internal Damper Window. You will be returned to the HVAC Window.

  10. Select Cancel to discard all field changes and close the Internal Damper window.