Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

Hull and Outfitting

Instrumentation, Electrical and P&ID Elements Matching

Instrumentation, Electrical and P&ID Elements Matching

  • Last UpdatedFeb 19, 2026
  • 1 minute read

Instrumentation, Electrical and P&ID element matching uses the following criteria:

  • If element data from the target database (for example, Schematics) had previously been imported into AVEVA Instrumentation, Electrical or P&ID, the Dabacon references will have been stored in there. If available these will be used as the first attempt to match.

  • If AVEVA Instrumentation, Electrical or P&ID data have previously been imported into the target database, and the integration UDA was available, the AVEVA Instrumentation, Electrical or P&ID database references will have been stored in the UDA. If available these will be used as the second attempt to match.

    Note: If the UDA is not available this step will be skipped. Refer to Integration UDA Definition for further information.

  • For Instrumentation, if the first two attempts have not generated a match, the third attempt will match on the default criteria of Tag or Loop as appropriate.

    Instruments from AVEVA Instrumentation can be matched to Dabacon types Instrument, Equipment and Sub-equipment. This gives the capability for example to separate instruments into inline, offline mounted and offline non-mounted.