P-line Name
- Last UpdatedDec 09, 2025
- 1 minute read
The p-line name is identified by the PKEY attribute of the annotation element. Where no p-line name is specified, the value 0 is taken to mean the neutral axis of the specified Design element. This may be NA, NAXI or ZAXI as set up in the Catalogue data. The value 0 is the default value for the PKEY attribute.
The PKEY attribute may be set directly using the following syntax:
PKEY word
The word given should refer to an existing p-line of the Design element, if that is set.
PKEY PPLINe word OF element_identifier
The specified p-line must exist. The specified element should be that given in the DDNM, if set.