Define Head and Tail
- Last UpdatedJan 22, 2026
- 2 minute read
-
From the Pipework main menu bar, select Create > Pipe to display the Create Pipe window:

-
In the Name box, input the name of the new Pipe.
-
By default the Primary System is No System, to change the type of primary system select a system from the Primary System drop-down list.
-
The Slope Ref specifies the slope reference attribute (the default is none). To change the slope reference attribute, select a slope reference from the Slope Ref: drop-down list.
-
By default the specification selected in Default Pipe Specification will be used but you can select an alternative specification, click Specifications. You can now change the Default Specifications, for further information, refer to Default Pipe Specification.
-
Click Attributes, the Pipe Attributes window is displayed, you can to view or modify the attributes of the Pipe element.

-
Click OK to save any changes and close the Pipe Attributes window, you are returned to the Create Pipe window.
-
Click Cancel on the Create Pipe window to discard changes and close the Create Pipe window, or OK to create a new pipe element in the Design database and close the window. The Create Branch window is displayed.