Rectangular Components - Weather Skirt
- Last UpdatedJan 13, 2026
- 2 minute read
The task of creating an HVAC Component is initiated from the HVAC Window.
-
Select Rectangular in the Categories dropdown list and then Weather Skirt in the Available Type dropdown list to display the Weather Skirt window:

You are required to input the following dimensions:
-
Skirt width AA
-
Skirt depth AB
-
Duct width LA
-
Duct depth LB
-
Dist from Leave
-
Height
-
A offset
-
B offset
-
First Extension
-
Last Extension
-
-
To visualize how the dimensions equate to the actual piece of HVAC, select Picture to display a detailed drawing for Rectangular Components Catalog Element - Weather Skirt.
Note: The fields will be pre-populated with default dimension. These dimension are governed by the details defined in the HVAC Catalog.
-
In the Aoff Direction enter the direction for the A offset relative to the Point of Origin. Valid directions are E (East), N (North), U (Up), -E (negative East), -N (negative North) or -U (Negative Up).X, Y, Z, -X, -Y or -Z.
-
In the Connect list, select Connect or Unchanged:
-
Select Connect (default when Create is selected) - connects the piece of HVAC to the previous one.
-
Select Unchanged (default when Modify is selected) - positions the component at the co-ordinates 0.00.
Note: Unchanged is usually used, when Modify is selected, it does not connect the component but positions it at 0.00, in effect in a floating position.
-
-
Select Defaults to reset all the fields back to when the Weather Skirt window was opened.
-
Select Fit to Next to orientate the Weather Skirt to automatically match the outlet (p-leave) of the previous piece of HVAC to the inlet (p-arrive) of the next piece.
-
Select OK to create the Weather Skirt component and close the Weather Skirt Window. You will be returned to the HVAC Window.
-