Setup Satellite
- Last UpdatedNov 27, 2025
- 3 minute read
After starting the Global daemon on the Hub the administrator can start another instance at a satellite. Once this has been done the administrator can begin customizing the way that communications between the two machines take place through WCF.

-
Conduct the following steps on the Hub machine:
-
Create a new transfer folder on the Hub machine.
Refer to the Global User Guide (section 4.6 Creating Location Files).
-
Using the SAM project as an example, navigate to the following folder:
C:\AVEVA\plant\PDMS12.1.1\project\Sample
-
Create a folder called SAM_SAT as a new transfer folder:
C:\AVEVA\plant\PDMS12.1.1\project\Sample\SAM_SAT
-
In the Sample folder open the evars batch file for the project inside a text editor.
The evars file for SAM is evarsSample.bat.
-
Create a new environment variable to point to the SAM_SAT folder:
set SAM_SAT=C:\AVEVA\plant\PDMS12.1.1\project\Sample\SAM_SAT
-
Launch the base product Admin module.
-
Create location in admin module

-
-
Conduct the following steps on the Satellite machine:
-
On the satellite make sure that the base product and Global Server have been pre-installed. Make sure that both have had the WCF enabled.
-
Copy the contents of the SAM_SAT transfer folder on the Hub:
C:\AVEVA\plant\PDMS12.1.1\project\Sample\SAM_SAT
... to the following location on the satellite:
C:\AVEVA\plant\PDMS12.1.1\project\Sample\
-
Copy the evarsSample.bat file from the Hub to the satellite project folder.
-
Modify the singleds.bat file on the satellite to point to the evarsSample.bat.
-
From the command line run the singleds.bat file by using the following syntax:
singleds start sam
-
On the satellite launch the base product Admin module.

-
Initialize the Satellite location by clicking Initialize Location.
The Hub and Satellite will now be communicating through Global by using WCF as the authentication provider.
-
-
From the satellite the administrator can test communication by issuing a ping command.
Important: There will be a delay when the first communication is established between nodes when using WCF.
-
From the Command Line in the Admin Module enter the following:

On the Hub machine the console window for the daemon will display a summary of communication between the two workstations: