Ensure each framework conforms to the following naming conventions. This enables the MDS application to navigate to the appropriate element and customize the application for both the Design and Draft stages of support production. Failure to apply these naming conventions may cause the applications to fail to produce supports.

Type

Name format

Example

SITE

/MDS/TEMPLATES

N/A

ZONE(S)

/MDS/FRAMES/{frameworktype}

/MDS/FRAMES/FT09

STRU

/MDS/{frameworktype}/{option}

/MDS/FT09/1

FRMW

/MDS/{frameworktype}/{option}-FRMW1

/MDS/FT09/1-FRMW1

SCTN

CROSSBAR

/MDS/{frameworktype}/{option}-BAR-1

/MDS/FT09/1-BAR-1

VERTICAL MEMBERS (if needed)

/MDS/{frameworktype}/{option}-V1 or V2

/MDS/FT09/1-V1

SUBS

/MDS/{frameworktype}/{option}-SUBS1

/MDS/FT01/1-SUBS1

SNODS

/MDS/{frameworktype}/{option}-V1/S1 or /V2/S1

/MDS/FT09/1-V1/S1

SJOI

/MDS/{frameworktype}/{option}-V1/S1/IJOINT1

/MDS/FT09/1-V1/S1/IJOINT1

There are two zones for each of these framework types: FT03, FT04, FT14, FT15, FT18, and FT19. Each one is supplied with the suffix -HORI or -VERT for example, /MDS/FRAMES/FT03-HORI.