Control Information
- Last UpdatedDec 15, 2023
- 2 minute read
This control information to the program are valid for Curved Part generation, Plate Interface and Plate Nesting.
Below follows a list of all the ip's that can be given. The complete file name should be assigned to the environment variable SBH_DEVOBJ_IP.
[CURVEIDENT]
[MARKGAP = <gap length>]
[TEXTHEIGHT = <height of the text>]
[MATERIALSYMBOL [LENGTH = <length> [PLACE = <place>] ] ]
[TEMPLATE [LENGTH = <length> [PLACE = <place>] ] ]
The ip's have the following meaning:
CURVEIDENT
If given, the identification for the curves will be given as follows:
|
|
frame |
FR <no> |
|
waterline |
WL <no> |
|
|
vertical |
BT <no> |
|
|
longitudinal |
L <no> |
|
|
transversal |
T <no> |
Necessary information must be stored in the plate.
MARKGAP = <gap length>
If given, marking contours will start and stop at the distance <gap length> from the outer contour. The distance is measured in the direction of the marking line.
TEXTHEIGHT = <height of the text>
Tells height of the text of the description names. If the ip is missing, then <height of the text> = 100.
[MATERIALSYMBOL [LENGTH = <length> [PLACE = <place>] ] ]
If this ip is given, material symbols will indicate on which side of the marking line the material will be placed. The corresponding information must be stored in the plate. For material side marking using an angle the addition LENGTH, <length> it is possible to change the length of the legs of the angle from the default value 30 mm to what is given. <place> denotes the distance from any of the end points. It is given as a fraction of the contour length, where a positive value denotes distance from the starting point and a negative value denotes distance from the ending point. The distance will never be less than twice the segment length.
TEMPLATE [LENGTH = <length> [PLACE = <place>] ]
This ip gives the same information for the templates as the above gives for marking curves. Double material symbols will be placed in the opposite direction because the templates have no thickness as default. If the ip is given, the template names will be substituted by the string "TPL." followed by the template number.
Below is an example of an ip-file:
|
Example: |
|---|
|
CURVEIDENT |