Geometry Sets

  • Last UpdatedJan 13, 2026
  • 8 minute read

The geometry sets have been created in project MDU. The following diagrams show what has been added and detail any properties that are being used. The MDS Administrator can add geometry using these properties if needed and add additional properties as necessary.

AT500 to AT700, BT500 to BT700, LT500 to LT700

Simple Box Representation

This is set to a length of 10, and uses the pipe outside diameter (OD) as the x and y length.

The three standard catalogue parameters have been added, nominal bore (NB), outside diameter (OD) and connection type (CONN) and 25 design parameters have been created. The following are the parameters that have been preset, that means, to -1. All other design parameters are set to 0 (zero), as shown in the form displayed above.

Number

Description

Dkey

22

Minimum Insulation

MNIN

23

Maximum Insulation

MXIN

24

Minimum Temperature

MINT

25

Maximum Temperature

MAXT

No user editable design parameters have been defined.

AN500 to AN569

Anchor for Shoes

Simple Anchor Representation

These user standards will ask for a pipe shoe to be identified so it will read the shoe parameters HEI (shoe height) and WID (flange width) in order to size the anchor. It will then ask for a section or box to be identified to read the anchor width across the section of box.

The three standard catalogue parameters have been added, nominal bore (NB), outside diameter (OD) and connection type (CONN) and 25 design parameters have been created. The following list the parameters that have been preset, that means, to -1, 100, 102 and 165. All other design parameters are set to 0 (zero), as shown in the form displayed above.

Number

Description

Dkey

1

Associated Shoe Height

HEI

2

Associated Shoe Flange Width

WID

3

Support Beam Flange Width

SBFW

22

Minimum Insulation

MNIN

23

Maximum Insulation

MXIN

24

Minimum Temperature

MINT

25

Maximum Temperature

MAXT

Design parameters 1, 2 and 3 have been declared as user editable (with an allowable range of 0 to 1000) and default values have been added as shown.

AN570 to AN639

Anchor for Pipes

Simple Box Representation

The three standard catalogue parameters have been added, nominal bore (NB), outside diameter (OD) and connection type (CONN) and 25 design parameters have been created. The following list the parameters that have been preset that means, to -1. All other design parameters are set to 0 (zero), as shown in the form displayed above.

Number

Description

Dkey

22

Minimum Insulation

MNIN

23

Maximum Insulation

MXIN

24

Minimum Temperature

MINT

25

Maximum Temperature

MAXT

No user editable design parameters have been defined.

GT500 to GT569

Guide for Shoes

Simple Guide Representation

These user standards will ask for a pipe shoe to be identified so it will read the shoe parameters HEI (shoe height) and WID (flange width) in order to size the guide.

The three standard catalogue parameters have been added, nominal bore (NB), outside diameter (OD) and connection type (CONN) and 25 design parameters have been created. The following list the parameters that have been preset, that means, to -1, 100 and 102. All other design parameters are set to 0 (zero), as shown in the form displayed above.

Number

Description

Dkey

1

Associated Shoe Height

HEI

2

Associated Shoe Flange Width

WID

3

Clearance

CLR

4

Length

LEN

22

Minimum Insulation

MNIN

23

Maximum Insulation

MXIN

24

Minimum Temperature

MINT

25

Maximum Temperature

MAXT

Design parameters 1, 2, 3 and 4 have been declared as user editable (with an allowable range of 0 to 1000) and default values have been added as shown.

GT570 to GT639

Guide for Pipes

Simple Guide Representation

The three standard catalogue parameters have been added, nominal bore (NB), outside diameter (OD) and connection type (CONN) and 25 design parameters have been created. The following list the parameters that have been preset, that means, to -1 and 0. All other design parameters are set to 0 (zero), as shown in the form displayed above.

Number

Description

Dkey

1

Height

HEI

2

Width

WID

3

Clearance

CLR

4

Length

LEN

22

Minimum Insulation

MNIN

23

Maximum Insulation

MXIN

24

Minimum Temperature

MINT

25

Maximum Temperature

MAXT

Design parameters 1, 2, 3 and 4 have been declared as user editable (with an allowable range of 0 to 1000) and default values have been added as shown.

ST500 to ST569

Stop for Shoes

Simple Stop Representation

These user standards will ask for a pipe shoe to be identified so it will read the shoe parameters HEI (shoe height) and WID (flange width) in order to size the anchor. It will then ask for a section or box to be identified to read the anchor width across the section of box.

The three standard catalogue parameters have been added, nominal bore (NB), outside diameter (OD) and connection type (CONN) and 25 design parameters have been created. The following list the parameters that have been preset, that means, to -1, 100 102 and 165. All other design parameters are set to 0 (zero), as shown in form displayed above.

Number

Description

Dkey

1

Associated Shoe Height

HEI

2

Associated Shoe Flange Width

WID

3

Support Beam Flange Width

SBFW

22

Minimum Insulation

MNIN

23

Maximum Insulation

MXIN

24

Minimum Temperature

MINT

25

Maximum Temperature

MAXT

Design parameters 1, 2 and 3 have been declared as user editable (with an allowable range of 0 to 1000) and default values have been added as shown.

ST570 to ST639

Stop for Pipes

Simple Box Representation

The three standard catalogue parameters have been added, nominal bore (NB), outside diameter (OD) and connection type (CONN) and 25 design parameters have been created. The following list the parameters that have been preset, that means, to -1. All other design parameters are set to 0 (zero) as shown in the form displayed above.

Number

Description

Dkey

22

Minimum Insulation

MNIN

23

Maximum Insulation

MXIN

24

Minimum Temperature

MINT

25

Maximum Temperature

MAXT

AN640 to AN700

Anchor for Trunnions

Simple Anchor Representation

The three standard catalogue parameters have been added, nominal bore (NB), outside diameter (OD) and connection type (CONN) and 25 design parameters have been created. The following list the parameters that have been preset. The plate length (PLEN), plate width (PWID) and plate thickness (PTHK) will be obtained from the identified base plate, that means, to -1. All other design parameters are set to 0 (zero) as shown in the form displayed above.

Number

Description

Dkey

1

Plate Length

PLEN

2

Plate Width

PWID

3

Plate Thickness

PTHK

22

Minimum Insulation

MNIN

23

Maximum Insulation

MXIN

24

Minimum Temperature

MINT

25

Maximum Temperature

MAXT

Design parameters 1, 2 and 3 have been declared as user editable (with an allowable range of 0 to 1000) and default values have been added as shown.

ST640 to ST700

Stop for Trunnions

Simple Stop Representation

The three standard catalogue parameters have been added, nominal bore (NB), outside diameter (OD) and connection type (CONN) and 25 design parameters have been created. The following list the parameters that have been preset. The plate length (PLEN), plate width (PWID) and plate thickness (PTHK) will be obtained from the identified base plate. All other design parameters are set to 0 (zero) as shown in the form displayed above.

Number

Description

Dkey

1

Plate Length

PLEN

2

Plate Width

PWID

3

Plate Thickness

PTHK

22

Minimum Insulation

MNIN

23

Maximum Insulation

MXIN

24

Minimum Temperature

MINT

25

Maximum Temperature

MAXT

Design parameters 1, 2 and 3 have been declared as user editable (with an allowable range of 0 to 1000) and default values have been added as shown.

GT640 to GT700

Guide for Trunnions

Simple Guide Representation

The three standard catalogue parameters have been added, nominal bore (NB), outside diameter (OD) and connection type (CONN) and 25 design parameters have been created. The following list the parameters that have been preset. The plate length (PLEN), plate width (PWID) and plate thickness (PTHK) will be obtained from the identified base plate. All other design parameters are set to 0 (zero) as shown in the form displayed above.

Number

Description

Dkey

1

Plate Length

PLEN

2

Plate Width

PWID

3

Plate Thickness

PTHK

22

Minimum Insulation

MNIN

23

Maximum Insulation

MXIN

24

Minimum Temperature

MINT

25

Maximum Temperature

MAXT

Design parameters 1, 2 and 3 have been declared as user editable (with an allowable range of 0 to 1000) and default values have been added as shown.