Bevel type 56 is an X-bevel type with one varying bevel angle. a is varying and b is fixed

Figure 1:52. Bevel type 56.

Relevant parameters: a, b, H, GAP, DIFF

Varying parameter: a (NB: b is fixed in this case)

a is defined as depending on CON with a fixed angular offset: a = DIFF - CON

The position of the "knee" of the X-bevel is defined by H = (h, hf). The interpretation is that the position of the knee is defined by a distance H = MAX(h, hf*T) (where T is the plate thickness). By setting h=0 then H will always be a factor times the plate thickness.

H> 0:

Means that the position of the knee is measured from the negative side of the bevel.

H <0:

Position measured from the positive side.

CON>0:

The positive side of the bevel is normally supposed to be turned upwards (as in the figure above).

CON<0:

Positive side downwards.

In this case a = DIFF - CON.